document Body blower fan on PL69 operating at all times.
The body-blower fan on the Ergoline Ambition, Soltron, Kiss or Flirt may operate at all times if the power wires of the fan become pinched between the fan housing and the end cap of the tanning system during installation. This situation can cause the wires to short together and create and...
rating 17 Dec, 2012 Comments: 0
document Ergoline, Soltron timer displaying Err.
By design the Ergoline and Soltron tanning systems deliver the "Err" message when: An incorrect access code has been entered.   If the display appear as `- - - - `, this is incorrect and the procedure must be repeated. The salon owner has changed the access code and...
rating 10 Dec, 2012 Comments: 0
document Fan Fuse
Most likely the is a short in the wires that run from the terminal strip to the fans. This may take some time to find. Start by locating the part of the bed that the problem is in by removing the wires on the fan terminal strip one at a time tell you find the problem wire. Trace that wire to...
rating 17 Dec, 2012 Comments: 0
document General Inforamtion: Operating with a Malfunctioning Membrane Switch
Only if you are useing an external timer to operate the bed. You will have to let the delay period expire befure the tanning system will turn on by itself. You will have no function for fan speeds or facial lamp adjustments if this unit has those options.
rating 29 Dec, 2012 Comments: 0
document General Information: Aqua Fresh/Vitalizer Kit (TAM 599)
The Aqua Fresh/Vitalizer products for use in Ergoline and Soltron units has been repackaged to include the following items. 1          Essence 1 ea.   Customized Label, Contents Label (USA only), Info. Tag, User's...
rating 17 Dec, 2012 Comments: 0
document General Information: Black Lamp Ends
When a lamp fires it ejects and burns carbon built up on the exterior of the filament in the ends of the lamps.  This is a normal occurance and cannot be prevented.  If you, however, are noticing excess amounts of darkening at the ends of the lamps it can indicate other issues...
rating 11 Dec, 2012 Comments: 0
document General Information: Choke-Start and Magnetic Ballast Differneces
There are several differences between a choke start system and a magnetic system. Choke Start Ballasts +One ballast powers one lamp +Starters are necessary +Require the use of Buck-Boost transformer in most applications Magetic Ballasts One...
rating 10 Dec, 2012 Comments: 0
document General Information: Do I need seperate neutral and ground connections?
No. Do not tie your neutral wire and ground wire together.  Not only is this an unsafe practice but it can, and will, interfere with proper operation of your tanning unit (now and in the future). Only install your tanning unit where there is both a ground and neutral wire...
rating 11 Dec, 2012 Comments: 0
document General Information: Extending Lamp Life
* Clean your acrylics thoroughly and periodically. Change them when necessary, not just when they are broken. See our acrylic FAQ section for more information on cleaning and changing suggestions. * Replace all fans as soon as possible after they fail. Keep all dust and debris cleaned...
rating 11 Dec, 2012 Comments: 0
document General Information: How to interrupt tanning session
Yes. All units manufactured by JK Products and Services are equiped with a display console that is cabable of being accessed by the user while they are using the tanning unit.  In general, the session can be interruped by pressing and holding the Stop or Start/Stop button...
rating 18 Dec, 2012 Comments: 0
document General Information: Intelitan CCS Controler Operation Levels
Three level of operation codes. Level one: Allows the operator to set beds. Level two: Allows the operator to set beds and view parameters. Level three: Allows the operator to set beds, view parameters and configure manager parameters. ...
rating 11 Dec, 2012 Comments: 0
document General Information: Intellitan Display Replacement
No. The program is stored  in the Main Power Board not the display of the unit. If connected to a Intellitan CCS IV or TMax Manager Pro controller, you will need to perfom a rescan by pressing CALL/MENU 999 and ENTER.  Once the unit finishes rescanning the network,...
rating 29 Dec, 2012 Comments: 0
document General Information: Lamp Color Variations
* Some manufacturers make lamps that have two different colored phosphors inside the same lamp. You may have seen advertisements of lamps that are 1/3 pink and 2/3 blue. * These lamps are usually designed for salon owners that have tanning equipment that did not originally come with a...
rating 11 Dec, 2012 Comments: 0
document General Information: Lamp Compatability
* Most states are required by either their state regulatory office or by the FDA to use either the original lamp that came in the tanning unit, or a compatible replacement. * Compatibility is set by the FDA guideline that states the following: -The replacement lamp's output must be...
rating 11 Dec, 2012 Comments: 0
document General Information: Lamp Life Expectancy
* Most manufacturers will have a rated life time for lamp they make. This information should be given to you at the time you purchase your lamps. Most lamp distributors have that information readily available. If not, ask them to contact the lamp manufacturer for you. Or, you can call them...
rating 11 Dec, 2012 Comments: 0
document General Information: Malfunctioning Lamps
* Lamp ends glowing: replace starters. * Flickering: usually caused by failed starters; replace. * Swirling: caused by impurities in the lamps. Run the unit through 2 or 3 sessions and they should disappear. * Orange or other colored "streaks": caused by air leaks through cracks...
rating 11 Dec, 2012 Comments: 0
document General Information: Maximum Exposure Time
* A bed was designed to operate with a particular type of lamp (or a compatible replacement) to achieve the session length it is labeled with. The following factors of bed design play a part in the session length: -Ballasts -Reflectors -Acrylics -Voltage -Distance between lamp and...
rating 11 Dec, 2012 Comments: 0
document General Information: New 55# spring for SunDash Units
In 2010 we changed the spring used in the 55# horizontal position in the SunDash beds. The spring is longer and bigger than the old spring. This spring has been through 1000's of hours of testing and field use and is 100% compatible with your tanning system.
rating 18 Dec, 2012 Comments: 0
document General Information: New lamps not lighting
* During shipping, it is possible that a lamp was damaged. Sometimes, the cracks may be so tiny that you cannot see them, but they allow the gases to escape. The lamp will not light. Contact the company you purchased the lamp from for their policy on freight damage. * A certain...
rating 11 Dec, 2012 Comments: 0
document General Information: Order Return Policy and Procedure
The following policies apply to new parts purchased from JK Global Service via sales, support, or service representatives as well as by electronic means. 1. Parts are guaranteed to be free of defect or damage for thirty (30) day from the date of purchase. Warranty claims...
rating 29 Dec, 2012 Comments: 0