CALL US: 1-800-445-0624
Showing: 1-10 of 10  
Articles
 
document General Information: Order Return Policy and Procedure
The following policies apply to new parts purchased from JK Global Service via sales, support, or service representatives as well as by electronic means. 1. Parts are guaranteed to be free of defect or damage for thirty (30) day from the date of purchase. Warranty claims...
rating 29 Dec, 2012 Comments: 0
document Issue: 94 on Display of Intellitan Tiemr
The message 94 displayed on the timer indicates an issue with the timer processor.  Power off the tanning system for several minutes.  If after restoring the power to the tanning system, the timer still displays 94, replacement of the timer is needed.
rating 18 Dec, 2012 Comments: 0
document Issue: Intellitan Timer Control Module is not accepting clean clear acknowledgement from tanning unit.
This is caused when parameters 09 and 17 have been set to a value of 01 but parameter 25 has not. To enable the clean clear feature and have it function from the tanning unit's controls parameters 09, 17, and 25 must all be set to a value of 01. For instructions on setting these...
rating 21 Dec, 2012 Comments: 0
document Issue: Network Problems and Power / Timer Boards
YES At times a bad power board or timer in a salon's network can cause problems. Units can drop off the network, not show up at all, or even appear / disappear. At times the unit might run fine off the network but when added cause problems to return.
rating 11 Dec, 2012 Comments: 0
document Issue: Tanning System immediately goes to dirty mode when Start button is pressed
A tanning system that is equipped with an Intelitan 3-button timer and shuts off immediately at the beginning of a session may be experiencing an issue with one of the following: 1.  The timer may be responding to a voltage on the network that is be perceived by the unit as...
rating 21 May, 2013 Comments: 0
document Issue: Tanning unit displays "Cool" as status on CCS controler
In regards to the Intellitan Timer Control Module, the Passion/Flair/Sundash, or the Sunrise Series, parameter 18 (1.8) has been set incorrectly and should be reset to 0. 
rating 11 Dec, 2012 Comments: 0
document Will the Shark Mattress bed work with a 3A timer being used as a single station Manager
YES... You can use a 3A as a single station Manager and run the Shark Matteress like a normal.
rating 11 Dec, 2012 Comments: 0
document Will the Shark Mattress bed work with a 3A timer in the room.
NO...... In the bed is the timer that has a safety making you hit the Start Button telling the bed you turned over. A third party timer does not have this technology.
rating 11 Dec, 2012 Comments: 0
document Will the Shark Mattress bed work with a Data Base timer in the room.
NO...... In the bed is the timer that has a safety making you hit the Start Button telling the bed you turned over. A third party timer does not have this technology.
rating 11 Dec, 2012 Comments: 0
document Will the Shark Mattress bed work with a FST timer in the room.
NO...... In the bed is the timer that has a safety making you hit the Start Button telling the bed you turned over. A third party timer does not have this technology.
rating 11 Dec, 2012 Comments: 0