CALL US: 1-800-445-0624
Showing: 1-20 of 127    »»
Articles
 
document Body blower fan on PL69 operating at all times.
The body-blower fan on the Ergoline Ambition, Soltron, Kiss or Flirt may operate at all times if the power wires of the fan become pinched between the fan housing and the end cap of the tanning system during installation. This situation can cause the wires to short together and create and...
rating 17 Dec, 2012 Comments: 0
document Body Fan
Please check these possible problems. Is there something in fan that is keeping it from turning? Is voltage getting to terminals X1.2 and X1.3 on the phase control PCB? Is the main PCB (11619) socket X11 getting 24V AC? Is there voltage to phase control PCB...
rating 13 Dec, 2012 Comments: 0
document Breaker Tripping at End of Tanning Session
Check for a bad effect lighting ballast. If the ballast was to short the breaker would trip when the relay that controls the ballast was engaged. For additional assistance contact your local branch, distributor, or the Global Support Team at 1-800-445-0624
rating 11 Dec, 2012 Comments: 0
document Buck Booster Wiring
If you will go to the Dongan web site at    http://www.dongan.com/products/buckboostframe.htm  This will show you downloads of the wiring diagrams for single and 3 phase dongan.
rating 29 Dec, 2012 Comments: 0
document Decor Lighting on Ergoline 650
To change the decor lighting option you can use the sevice module or the overhead control panel. Information on how to change these options are in your owners manual. To enter the service mode on the overhead, start by simultaneously pressing the - (minus) on both...
rating 29 Dec, 2012 Comments: 0
document Distilled Water in Aqua Mist/Vitalizer System
We strongly recommend using only OEM replacement canisters for use with the Aqua Mist/Vitializer system. The OEM replacement canisters contain a specially formulated antibacterial mixutre required for your customer's health and safety. Do not use any other substance in the Aqua...
rating 10 Dec, 2012 Comments: 0
document Does the VIT facial filter glass have to be installed in any particular way?
Yes.  The filter glass panel must be installed such that the Logo is legible from the outside(i.e. you can read it while laying in the unit with all components fully assembled). If the filter glass panel has no logo, the glass should be installed so that the part number etched on...
rating 29 Dec, 2012 Comments: 0
document Ergoline, Soltron timer displaying Err.
By design the Ergoline and Soltron tanning systems deliver the "Err" message when: An incorrect access code has been entered.   If the display appear as `- - - - `, this is incorrect and the procedure must be repeated. The salon owner has changed the access code and...
rating 10 Dec, 2012 Comments: 0
document Error Code: 002, 003, 004, 005, 008 Dead-Lock Error
The only means of resetting error codes (0002, 0004, 0005, 0008) is by cycling power to the tanning units. Without cycling power to the tanning units, the error code cannot be reset(using ServicePC, resetting limit switches, etc.). The error code does not have anything to do with the tanning...
rating 13 Dec, 2012 Comments: 0
document Error Code: E001 or E002 on Ergoline Classic series unit
The following are known to cause the before mentioned errors: E001 ~ is the error code which the system displays when the water/condensation tank is full in the tanning system. E002 ~ is the error code which the system displays when it determines the water pump associated with...
rating 10 Dec, 2012 Comments: 0
document Error Code: E005
Error E005 is displayed when the system detects an error with the temperature switch(s) for the heating element relating to the temptronic system.  This can include a faulty switch, heating element, or temptronic board.  If the cause of the error is determined to be the element...
rating 11 Dec, 2012 Comments: 0
document Error Code: E010
Error E010 is displayed during startup if one (or more) temperature sensors is not working or a wire from the safety circuit is not making contact. To determine the cause first do the following: 1. Lower the bow shaped tube (panel located between the canopy and side...
rating 29 Dec, 2012 Comments: 0
document Error Code: E010 E011 E012
Theses errors indicate an issue with the temperature sensor or the information returned from the sensor.  E010  Error temperature fuse facial tanner E011  Error temperature fuse canopy E012  Error temperature fuse lower part Please check to ensure that...
rating 17 Dec, 2012 Comments: 0
document Error Code: E018 E019
These error messages are displayed when the low pressure lamp temperature exceeds the tolerence allowed by the system. E018 Indicates that the lamp temperature sensor is reporting a lamp temperature less than that of the room temperature. E019 Indicates that the lamp temperature sensor...
rating 18 Dec, 2012 Comments: 0
document Error Code: E020 - E039
E020 : Filter glass facial tanner rear and middle canopy Filter glass missing, not installed properly or faulty limit swich. E021 : Filter glass facial tanner front Filter glass missing, not installed properly or faulty limit swich. E022 : Filter glass...
rating 17 Dec, 2012 Comments: 0
document Error Code: E022 Side Section Facial Filter Glass
If error E022 is displayed, the limit switch for the filterglass on the High Pressure lamp is open on the side section. Check to make sure that filterglass is seated properly on the spring load limit switch. If this does not clear the error check for continuity on pins 4 and 6 on plug...
rating 18 Dec, 2012 Comments: 0
document Error Code: E030 or E031 on Ergoline Lounge/Soltron Shuttle
E030 and E031 are error messages that Ergoline Lounge or Soltron Shuttle will display when an acrylic panel is improperly latched or when there is a problem with a limit switch located inside each panel and door. E030 is displayed when the limit switch is not engaged and/or acrylic panel...
rating 29 Dec, 2012 Comments: 0
document Error Code: E034 on a Ergoline Classic E600 and E650
Error E034 on a Ergoline Classic E600 and E650 is displayed when there is a technical issue with the limit switch associated with the acrylic assemblies (base, side, top and shoulder tanner).  To address this error message, please confirm the following: 1. Confirm that the above...
rating 21 Dec, 2012 Comments: 0
document Error Code: E039
Error code E039 indicates that the limit switch on the shoulder tanner is open.  Please physically remove and reinstall the cover for the shoulder tanner unit.  If the issue persist after reinstalling the shoulder tanner, you should check the other acrylics in the unit by physically...
rating 29 Dec, 2012 Comments: 0
document Error Code: E050 & E051
These errors indiacate that a decorative panel on the outside of the unit is not properly installed. E050 Safety switch filter panel facial tanner top front. Front decore not properly installed or faulty limit switch(s) E051 Safety switch filter panel facial tanner top right...
rating 12 Dec, 2012 Comments: 0

Showing: 1-20 of 127    »»

RSS

Contraindication: This product is contraindicated for use on persons under the age of 18 years. "Contraindication: This product must not be used if skin lesions or open wounds are present." "Warning: This product should not be used on individuals who have had skin cancer or have a family history of skin cancer." "Warning: Persons repeatedly exposed to UV radiation should be regularly evaluated for skin cancer.