ETS Units 2002 and Newer: Error 92

Article ID: 1060
Last updated: 03 Jan, 2013
Revision: 1
Add comment
Views: 0
Comments: 0

ERROR 92 The bed is off when it should be on.

Current sensor indicating unit is off when it should be on. The contactor relay is not engaged, therefor the lamps will not come on. This can be caused by low power or by a faulty contactor relay.  Occasionally, it is caused by a faulty current sensor that is not reporting that there really is power going through the bed. The error that occurs actually causes the lamps to go back off. If you see the bed run for about 30-60 seconds and then the lamps turn off, you may have a faulty current sensor or a loose wire connection somewhere.

This article was:  
Prev   Next
Timers/Networking     ETS Units 2002 and Newer: Error 93

RSS

Contraindication: This product is contraindicated for use on persons under the age of 18 years. "Contraindication: This product must not be used if skin lesions or open wounds are present." "Warning: This product should not be used on individuals who have had skin cancer or have a family history of skin cancer." "Warning: Persons repeatedly exposed to UV radiation should be regularly evaluated for skin cancer.